中文简体 English

Telephone: ++86 029-68229739

E-mail: sales@oren-electric.com

Current location: Home > Product
    Resistive Portable Load Bank

    Resistive Portable Load Bank

    1) User could load any power within rated power, can test stable state three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, running time of generating set. 2) Whether load/unload by local control panel or by PC software control, user can pre-set the power then press the master load button.

    OREN-AC400V-7KW Rack Mounted Load Bank

    OREN-AC400V-7KW Rack Mounted Load Bank

    OREN-AC400V-7 KW-R ac load bank is suitable for on-load testing in data center room

    Liquid cooling AC load Bank

    Liquid cooling AC load Bank

    The key facilities of the data center are the power distribution and air conditioning system, and the comprehensive test is the on-load test of the key facilities. The IT equipment is gradually installed after the data center is delivered, that is, there is no IT load in the data center at the time of construction acceptance, so many problems resulting in critical facilities cannot be exposed. The liquid cooled dummy load can simulate the system

    OREN-AC400V-7KW Rack Mounted Load Bank

    OREN-AC400V-7KW Rack Mounted Load Bank

    OREN-AC400V-7 KW-R ac load bank is suitable for on-load testing in data center room

    2500KW Resistive load bank

    2500KW Resistive load bank

    The system consists of 1 sets of 2500KW Load Bank, The is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on

    DC48/54V-2000A-R LOAD BANK

    DC48/54V-2000A-R LOAD BANK

    OREN-DC48/54V-2000A-R LOAD BANK which is suitable for discharge test of large-capacity batteries, The control system adopts local manual control by push buttons and provides protection against overvoltage, overcurrent, and overtemperature.

    Resistive DC Load Bank

    Resistive DC Load Bank

    It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, AC & DC generator, rectifier, transformers, inverter etc working in good condition if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.

    RLC Load Bank

    RLC Load Bank

    OREN-RLC load bank is designed to meet the requirements of anti-islanding test for grid-connected inverters. It can simulate various resistance/inductance/capacitance AC loads, simulate various working environments of the inverter, detect the actual output power and load capacity of the inverter, detect and debug the resonance point of the photovoltaic(PV) inverter, overload protection test, and overload protection test.

    Resistive&Inductive(RL) Load Bank

    Resistive&Inductive(RL) Load Bank

    OREN-Resistive&Inductive(RL) Load Bank is mainly used for Generator testing at power station, AC power supply, data center and other testing,May detect the performance of different loads of the AC power supply of the power station.The power input is uniformly optimized to meet the needs of different loads.